Root cause: mbedtls SSL buffers (16KB) couldn't allocate from fragmented
internal RAM (largest block 8KB). Fix by lowering SPIRAM_MALLOC_ALWAYSINTERNAL
from 16KB to 4KB, allowing SSL buffers to go to PSRAM.
Additional fixes:
- DNS server binds to AP IP only (prevents self-hijacking)
- start_services() moved from esp_timer (2KB stack) to dedicated FreeRTOS
task (16KB stack) — was causing stack overflow with dynamic buffers
- Mint health probe now logs errors and exposes last_err in API
- Debug endpoint shows internal/PSRAM heap breakdown and DNS resolve test
- Enabled CONFIG_MBEDTLS_DYNAMIC_BUFFER for better memory management
- Board C config: mint_url → testnut-nutshell.mints.orangesync.tech
|
|
Local Nostr relay (NIP-01) on port 4869 with LittleFS 4MB storage.
All events published locally first, then synced to public relays via REQ-diff.
Relay selection via NIP-11 HTTP probing with NIP-77 scoring and auto-failover.
Components:
- wisp_relay: 16-file local relay (ws_server, storage_engine, sub_manager,
broadcaster, relay_validator, router, handlers, rate_limiter, nip11,
deletion, flash_monitor, relay_types)
- esp_littlefs: LittleFS VFS integration (git submodule)
- negentropy: for future NIP-77 binary sync (git submodule)
New source files:
- local_relay.c/h: thin wrapper for relay init/start/publish
- relay_selector.c/h: NIP-11 probe + scoring + auto-failover
- sync_manager.c/h: REQ-diff sync (primary 30min, fallback 6h)
Bug fixes:
- config.c: use-after-free (cJSON_Delete before seed_relays/sync parsing)
- local_relay: moved init to app_main for boot-time start (not gated on STA IP)
Flash layout: 4MB LittleFS partition at 0x500000 for relay_store
Test results (Board B, live hardware):
- Smoke: ping + HTTP 4869 + NIP-11: PASS
- NIP-11 info document: 10/11 PASS
- WS pub/sub (connect, REQ/EOSE, EVENT/OK, CLOSE, concurrent): 6/6 PASS
- Unit tests (relay_validator + relay_selector): 13/13 PASS
Hardware test make targets in physical-router-test-automation/:
- make relay-build, relay-flash-b, relay-test-smoke/nip11/pubsub/sync/full
|
|
- Add identity.c/h: HMAC-SHA512 derivation from nsec → npub, STA/AP MAC, SSID, AP IP
- Add nostr_event.c/h: NIP-01 event serialization + Schnorr signing (BIP-340)
- Add geohash.c/h: lat/lon to geohash encoding
- Add wifistr.c/h: kind 38787 event builder + WebSocket publish to Nostr relays
- Update config.c/h: nsec-based identity, Nostr relay/geo config, remove static SSID/IP
- Replace custom mbedTLS wallet with nucula library (libsecp256k1)
- Remove wallet.c/h, wallet_persist.c/h (replaced by nucula_lib component)
- Verified on Board A: derived SSID, captive portal, payment, wallet, wifistr publish
|
|
- Fix WiFi init order: netif creation before esp_wifi_init, set mode before set_config
- Replace broken netif input filter with NAPT on/off per authentication state
- NAPT disabled by default, enabled when client granted, disabled on revoke
- Fix test helpers: use -I wlp59s0 for ping, handle nslookup exit code 1
- All 20 API tests pass, all 6 smoke tests pass
|